17
WT-9001 IP65 GSM Remote Monitorin
& Remote Control S
stem
COPYRIGHT ©2011
WITURA CORPORATION SDN BHD
Function 8:
Turn off output relay 6. The unit will send SMS if the relay 6 is ON at previous state.
If not it won’t send SMS.
Function 9:
Turn off output relay 7. The unit will send SMS if the relay 7 is ON at previous state.
If not it won’t send SMS.
Function 10:
Turn off output relay 8. The unit will send SMS if the relay 8 is ON at previous state.
If not it won’t send SMS.
Example:
To setup 2 alarm set points at 10% and 90% for input 1 and both set points will also
trigger an alarm message; you would send the 2 following SMS command to the unit.
*ALP11#10,3
*ALP12#90,3
Note: The perform functions work on GSM mode only
Note: This Function Works On Analogue Input & GSM Mode Only
The alarm set point message can be edited and programmed up to 50 characters long.
You can change the displayed text by sending the following commands by SMS message
to the unit.
Note: Only support normal abc/ABC English text, no special characters.
Text Command:
*SDF[N]#XXXXX…
N stands for Input number 1 - 4
XXXXX… stands for the display text that you want to program. Maximum 50 characters
To check the programmed texts, you can send *SDF?#[N]
Example:
If you want the alert message to display “Fuel Alert!” for input 1 when the monitored
signal reaches the set point, you would send the following SMS message to the unit.
*SDF1#Fuel Alert!
Note: When signal reaches the set point, the system will send the programmable alert messages
and also report the set point level. For example: Fuel Alert!:10%
5.4.4 Editing the Alarm Set Point Message Content