18
WT-1011RC IP65 GSM Remote Controller
And Alarm S
stem
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
All inputs can be programmed to behave differently, it can count the input active high
pulses, generate an alarm message or activate relay. To program the input, you can
send the following commands by SMS message to the unit.
Text Command:
*CTC1#F1
*CTC2#F2
*CTC1# stands for input number 1
*CTC2# stands for input number 2
F1 stands for selectable input function 1 – 2
F2 stands for selectable input function 1 - 8
Input 1 Selectable Function Descriptions (F1):
Function 1:
Function as pulse counter
Function 2:
Function as pulse counter
Generates a programmable input alert message (*STR1#) once input triggered
Generates a programmable input alert message (*STO1#) once input returned to
normal
Input 2 Selectable Function Descriptions (F2):
Function 1:
Function as pulse counter
Function 2:
Function as pulse counter
Activates the output relay 2 to stay ON
Sends a counter alert message once alarm counter reaches the alert value
Audible alarm will sound if the alarms function is turned on (*ALM2#1)
* For more details on function *ALM[N]# please refer to Alarm Settings on page
5.5.6 Setting the Feature of Input