WT-9002 IP65 User Manual
WT-9002 IP65 – USER MANUAL – Rev.2.0 – Technical Support: [email protected]
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
Multi-features Inputs
These inputs can be programmed to behave differently, it can count input active high pulses, generate an alarm
or activate relays. It needs to be activated first by SMS to start using the commands.
Function Command for Input 1 - *CTC1#X
Function Command for Input 2 - *CTC2#X
X stands for Functions No. 18
Function No. 1 (Default)
- Count whenever it receives active high pulses
Function No. 2
- Count whenever it receives active high pulses
- Activates Relay 1 (When Function No. 2 is apply on Input 1) or Activates Relay 2 (When Function No. 2 is
apply on Input 2)
Function No.
3
- Count whenever it receives active high pulses
- Activates Relay 1 (When Function No. 3 is apply on Input 1) or Activates Relay 2 (When Function No.
3 is apply on Input 2)
- Return a SMS: ECLK1<OK>
- Alarm will sound
Function No.
4
- Count whenever it receives active high pulses
- When received an active high pulse, it will send an active high pulse for 1 second out from I/O port
Function No.
5
- Count whenever it receives active high pulses
- When received an active high pulse, it will send an active high pulse for 1 second out from I/O port
- Return a SMS: OUT3<ON>
- Alarm will sound
Function No.
6
- Count whenever it receives active high pulses
- Activates Relay 2 (When Function No. 6 is apply on Input 1) or Activates Relay 1 (When Function No.
6 is apply on Input 2)
- Sends a SMS when counter reaches the alert value
- Alarm will sound when the counter reaches the alert value
Function No.
7
- Count whenever it receives active high pulses
- Activates Relay 1 and Relay 2
- Sends a SMS when counter reaches the alert value
- Alarm will sound when the counter reaches the alert value
Function No. 8
- Count whenever it receives active high pulses
- Activates Relay 1 to stay ON (When Function No. 8 is apply on Input 1) or Activates Relay 2 to stay
ON (When Function No. 8 is apply on Input 2)
- Return a SMS: ECLK1:
ALWAYS-ON
- Alarm will sound
Note: It can be turned off by simply sends a SMS command *RLY1#00000 or *RLY2#00000