30
WT-9002 IP65 User Manual
WT-9002 IP65 – USER MANUAL – Rev.2.0 – Technical Support: [email protected]
COPYRIGHT ©2010
WITURA CORPORATION SDN BHD
The unit is able to send alert message to the administrator in the event the main power
is out / turned off. When the main power is restored it can notify the administrator again
the main power is on.
When main power OFF
The unit will send a message: ACP-OFF
Note: At the same time, it will send an ALWAYS high pulse out from I/O port. Alarm will
sound.
When main power restored
The unit will send a message: ACP-ON
It is possible to adjust the speaker volume (from level 0 to 6) of the intercom by sending
the following SMS command. Factory Default: 4
Example: Sending the following SMS Command
*SOUD#5 – Adjust the volume to 5
Example of Returned Message:
SOUND:<5>
It is possible to adjust the microphone volume (from level 0 to 9) of the intercom by
sending the following SMS command. Factory Default: 2
Example: Sending the following SMS Command
*MIC0#5 – Adjust the volume to 5
4.25 AC POWER ON/OFF ALERT MESSAGING
4.26 ADJUSTING THE SPEAKER VOLUME OF INTERCOM
4.27 ADJUSTING THE MICROPHONE VOLUME OF INTERCOM
Note:0Zero