Witura WT-1010C2 Manual de usuario Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 48
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
WT
-
101
0
C2
USER MANUAL
IN1: OP: CL: AL:
CA:
IN1: OP: 1 CL: 1 AL: 1
CA: 1
Example: Setting the input 1 to generate an SMS, call the administrators
and sound the audible alarm when it triggered.
Simply input 1111#
IN1: OP: 1 CL: 1 AL: 1
CA: 1 OK
Note: “OP” stands for generation of SMS when input triggered (Open)
“CL” stands for generation of SMS when input triggered (Close)
“AL” stands for sounding the audible alarm when input triggered
“CA” stands for calling the administrators when input triggered
Value: ON (1) or OFF (0)
You may continue to activate relay 2 or relay 3 by pressing *25* or *26*
19)
Activate Output Relay to stay on for a specific time
To activate output relay 1 to stay on for a specific time, you can press *21* to
proceed.
RLY1: RE:
RLY1: 00050 RE: 1
Example: To activate relay 1 to stay on for 50 seconds and with SMS
reply from the unit after relay has turned off
Simply input 000501#
21
WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : [email protected]
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
Vista de pagina 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 47 48

Comentarios a estos manuales

Sin comentarios